The duplicate key value is (GUID)” error in upgrade logs for installations that had multiple Linux server with the same credentials registered at the time of Veeam Backup & Replication upgrade from version 6.5 to 7.0. Cannot insert duplicate key in object ‘’. Restoring a V10 configuration backup into a V11 backup server fails with the “ Violation of PRIMARY KEY constraint ‘PK_Credentials.Onsite’.This change does not constitute the official support for these platforms, which is planned for version 11a. Various product functionality should no longer outright refuse to work with pre-release builds of Windows 10 21H1 and Windows Server 2022 builds and will instead attempt to process them using the existing logic created for previous OS versions.Archive Tier no longer requires minimum remaining storage time of at least 180 days for GFS backups offloaded to Amazon Glacier Deep Archive, as even when taking into account its early deletion fee, this storage class ends up being cheaper than Amazon Glacier regardless of the remaining storage time.Added support for VMware Distributed Switch (VDS) version 7.0 in VMware NSX-T 3.0 or later environments for VM restore operations.Note: CDP functionality is not yet supported with vSphere 7.0 U2 due to the I/O filter drivers signing infrastructure issue at VMware, support will be added in the next cumulative patch. Added VMware vSphere 7.0 U2 support including new vSphere API version awareness and virtual hardware version 19 compatibility.Veeam Cloud Connect: reduced load on vCloud Director servers when vCD-integrated tenants are used returned support for the SkipLinuxAgentRemoval behavior modifier for Linux-based Cloud Connect repositories configured not to use the persistent data mover.

In certain backup job configurations, backups of machines no longer present in the environment can be deleted by the retention policy even if the “Remove deleted items after” checkbox is not selected in the advanced job settings.Processing of vSphere VMs with certain special virtual hardware devices (like Watchdog Timer or Precision Clock) fails with “ The specified type was not recognized” error.Repository friendly name cannot be set via REST API for the self-service backup portal management.Addressed NSX-T interoperability issue with certain vCloud Director configurations.Added VMware vSphere 7.0 U2 support for CDP functionality.This cumulative patch includes the following new features, enhancements and fixes for the original V11 GA builds: